Features of special transformer for medium frequency furnace
1.
Energy saving, high efficiency and environmental protection. According to the
requirements of the national mandatory standard "Power Transformer Energy
Efficiency Limits and Energy Efficiency Grades", in the process of power
grid construction, transformers have played a very important role. Power
transformers are key electrical equipment for power transmission, and
transformer self-consumption accounts for 30% to 40% of grid losses. On the one
hand, it can effectively reduce the energy consumption and noise during
operation. On the other hand, it should minimize the use of raw materials such
as copper, iron, oil, and insulating parts to avoid excessive waste of
resources. The power saving effect is obvi ous, and the noise is low (<65dB).
2. Anti-harmonic. The special transformer
for medium frequency furnace adopts a 12-pulse transformer to eliminate the
harmonics of the grid-side winding. The harmonic is a sine wave, and each
harmonic has a different frequency, amplitude and phase angle. Harmonics can be
divided into even-order and odd-order. The 3rd, 5th, and 7th order are
odd-order harmonics, while 2, 4, 6, 8 and so on are even-order harmonics. For
example, when the fundamental wave is 50Hz, 2 The sub-harmonic is 100Hz, and
the third harmonic is 150Hz. Generally speaking, odd harmonics cause more harm
than even harmonics. The product combines load characteristics, grid voltage
fluctuations, and atmospheric overvoltage conditions, and determines a
reasonable and reliable insulation level and insulation model according to the
load status of the rectifier transformer to fully ensure the electrical performance
of the product is reliable and stable. Product environmental safety factor
≥1.67.
3. No heat, strong overload capacity. In electrical production, in the production and materials of special transformers for medium frequency furnaces, through accurate calculation of technical parameters, high-quality, high-permeability, low-loss, high-quality silicon steel sheets are used to manufacture cores and wires, and the ratio of copper to iron is determined through scientific methods. The upper guarantee transformer has lower no-load loss and low noise performance. Through the "open source and throttling" method, the heat dissipation capacity of the transformer and the effective control of the current are increased to ensure the stable and efficient operation of the transformer. Advanced product design, strictly control the temperature rise of the heating part and heating point of the product, and leave a sufficient temperature rise margin. If necessary, add an axial oil channel in the coil, and choose the cooling method according to the coil load loss value and reasonable The oil flow is distributed to achieve the best cooling effect, and the main temperature rise indicators are at least 5°C lower than the national standard. The coil and lead adopt copper wire, and the current density is lower. The product has strong overload capability and overvoltage capability, and can operate safely for a long time under rated load conditions, and can operate safely under full load for a long time under 110% overvoltage conditions (ambient temperature 40℃); terminals connected to the transformer and the motor It can withstand 1.5 times the rated current for 5S. Product design and manufacturing fully consider the load characteristics, and meet the overload requirements in terms of temperature rise, insulation performance and accessory selection.
评论