Technical characteristics and advantages of one-to-two medium frequency smelting furnace
One-to-two medium frequency melting furnace, as its name implies, is one power supply with two furnaces working at
the same time, power is distributed at will, one for smelting, one for heat
preservation, continuous melting, when needed, it can be kept at an accurate
temperature, heating up, tempering, etc., maximum Limit increase in production.
Technical characteristics
The one-to-two medium frequency furnace adopts the "series inverter thyristor medium frequency power supply technology". Although the thyristor fully controlled rectification furnace is used, it does not use it for voltage regulation. It only uses it to achieve a soft start and act as an electronic switch in the event of a fault to quickly cut off the power supply. , In normal operation, the thyristor is always in the fully-on state, so that the power supply of the grid has a high power factor and reduces harmonic interference. The rectifier control circuit adopts a digital shift trigger circuit. The digital shift trigger circuit has the advantages of good repeatability, good stability, good symmetry, strong anti-interference ability, and convenient debugging. If the digital quantity setting is used, it can still realize remote control.
First, high efficiency
The series inverter adopts a half-bridge
circuit, the number of main circuit components is relatively reduced, and there
is a high power factor, so it has a higher power.
Good starting characteristics can be
started at will under full load and heavy load, and the starting success rate
is 100%. Improve the power factor to ensure that the power factor reaches 95%
at any power.
Constant power output. The power output
adopts constant control. During the smelting process, when the load and
temperature change, the load is always full power output, thus shortening the
smelting time.
Second, it has complete protection and
operating status monitoring system
For example use sensors to obtain signals
for incoming line current, voltage, channel current, and voltage, and provide
double closed-loop digital circuits for current limiting, voltage limiting,
excessive overvoltage repeated protection, water temperature, and water pressure
protection, and so on. Both KK thyristor and KP thyristor have self-turn-off
time protection.
Third, there is a complete detection system
The working temperature of the inverter and the filter capacitor is monitored by a temperature switch meter. Once the cooling
water temperature exceeds the set value or there is a water circuit failure, an
alarm will be issued and the power supply will be cut off. The power supply
cooling water input has a water pressure relay electrical control, and the
cooling water output has a temperature switch meter to monitor Undervoltage,
and an alarm will be issued and the power supply will be cut off if over
temperature.
Huaxin Electric Furnace latest thyristor
series-connected one-to-two medium frequency power supply
1. Use occasion: It is suitable for occasions where two furnaces of molten steel need to be produced at the same
time for casting relatively large workpieces. It is suitable for the working
mode of one power supply and two furnace bodies working at the same time, one
for smelting and the other for heat preservation. It is suitable for casting
production line that requires continuous and uninterrupted tapping of molten
steel to be compatible with the production rhythm of sand molds.
2. Compared with the traditional parallel connection: it can work in a detuned state and adjust the output power through frequency modulation. In the event of any failure, the inverter thyristor will not be burnt. It can adapt to the working mode of heavy load start-up operation. The thyristor of the rectifier bridge is always in the fully-on state during the entire operation of the equipment, so the power factor of the entire smelting process is above 0.96. Improve overall operating efficiency and save operating costs. The resonant tank current is close to the DC current and is relatively small, so the loss on the overall line is relatively small, which improves the overall efficiency. The work caused by frequent replacement of water-cooled cables or furnace switches is eliminated, and the labor intensity of workers is reduced.